CC488 | Quick Reference Guide | 2.0 Programming Parameters
2.13.3
Polarity (Modes)
Option
Description
0
Disabled
1
Normally open, going low
2
Normally open, pulsing low
3
Normally open, one shot low
4
Normally open, one shot low (reset)
5
Normally open, one shot low (re-trigger)
6
Normally open, latching low
7
Reserved
8
Normally low, going open
9
Normally low, pulsing open
10
Normally low, one shot open
11
Normally low, one shot open (reset)
12
Normally low, one shot open (re-trigger)
13
Normally low, latching open
2.13.4
Time Base
Option
Description
1
200 ms
2
1 sec.
3
1 min.
4
1 hr.
2.13.5
Time Base Multiplier
Enter a value between 01 and 99.
2.13.6
One Shot Mode
When you program the output polarity as one
shot, the time base is multiplied by the time base
multiplier. (For example, if the time base = 2 and
the multiplier = 05, the output operates for 10 sec.)
2.13.7
Pulsing Mode
When you program the output polarity as pulsing,
the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is
the time base x the multiplier. (For example, if you
want the output to pulse 1 sec. ON and 5 sec.
OFF, you would program time base as one and the
multiplier as five.)
2.14
Time Programming
2.14.1
Entry Time 1
Location
410 to 411
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
2.14.2
Entry Time 2
412 to 413
Location
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
2.14.3
Exit Time (AWAY/STAY Modes)
Location
414 to 415
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
Bosch Security Systems | 6/04 | 4998152446B
Location
Default
410
4
411
1
Location
Default
412
8
413
2
Location
Default
414
12
415
3
2.14.4
Entry Guard Time For STAY Mode
Location
416 to 417
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
2.14.5
Delay Alarm Report Time
Location
418 to 419
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
2.14.6
Sensor Watch Time
420 to 421
Location
Increments of days (tens digit)
Increments of days (units digit)
2.14.7
Codepad Lockout Time
Location
422
Default
0
Increments of 10 sec. (0 sec. to 150 sec.)
2.14.8
Siren Run Time
423
Location
Default
5
Increments of 1 min. (0 min. to 15 min.)
2.14.9
Siren Sound Rate
Location
424
Default
7
0 = Slowest frequency
15 = Fastest frequency
2.14.10
Auto Arming Pre-Alert Time
Location
425
1
Default
Increments of 5 min. (0 min. to 75 min.)
2.14.11
Auto Arming Time
Location
426 to 429
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
2.14.12
Auto Disarming Time
430 to 433
Location
Hour of the day (tens digit)
Hour of the day (units digit)
Minute of the day (tens digit)
Minute of the day (units digit)
2.14.13
Kiss-Off Wait Time
Location
434
Default
3
Increments of 500 ms (500 ms = 8 sec.)
EN | 18
Location
Default
416
0
417
0
Location
Default
418
0
419
0
Location
Default
420
0
421
0
Location
Default
426
0
427
0
428
0
429
0
Location
Default
430
0
431
0
432
0
433
0