Figure 13: Split EOL Resistors Using Two N/O
Contacts
1
2
3
1 – +12 V
2 – Zone Input
3 – Zone
4 – EOL 3k3
14.3

Zone Programming

The programming information for each zone is
stored in seven locations divided into three groups.
The first three locations determine how the zone
operates, the next two locations set up a number of
zone options, and the last two locations store the
dialer reporting information for the zone.
Zone Operating Information
These locations store the Zone Type (for example,
Delay-1, Instant, or 24-Hour), the Zone Pulse Count,
and the Zone Pulse Count Time. The Zone Pulse
Count specifies the number of times the zone must
activate within the time specified in the Zone Pulse
Count Time. Refer to Sections 14.3.2 Zone Types,
14.3.3 Zone Pulse Count, and 14.3.4 Zone Pulse Count
Time on pages 59 through 61 for more information.
Zone Options
These two locations allow you to select from a
number of options. Refer to Sections 14.3.5 Zone
Options 1 on page 61 and 14.3.7 Zone Options 2 on
page 63 for more information.
Zone Reporting Information
This information includes the locations for the Zone
Report Code and the Zone Dialer Options.
The Zone Report Code determines if the control
panel sends Alarm Reports for the zone. Refer to
Section 14.3.8 Zone Report Code on page 64 for more
information.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Zone Information
5
4
6
7
8
8
5 – EOL 6K8
6 – EOL 1K5
7 – EOL 4K7
8 – N/O
The Zone Dialer Options location enables you to
specify how a zone reports to a base station receiver.
Refer to Section 14.3.9 Zone Dialer Options on page 64
for more information.

14.3.1 ICP-CC488 Zone Defaults

Location
267 to 378
Zone #01 (Default = Delay–1)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone #02 (Default = Handover)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone #03 (Default = Handover)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone #04 (Default = Handover)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone #05 (Default = Instant)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone #06 (Default = Instant)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
EN | 58
Location
Default
267
2
268
0
269
0
270
1
271
14
272
1
273
1
274
1
275
0
276
0
277
1
278
14
279
1
280
1
281
1
282
0
283
0
284
1
285
14
286
1
287
1
288
1
289
0
290
0
291
1
292
14
293
1
294
1
295
0
296
0
297
0
298
1
299
14
300
1
301
1
302
0
303
0
304
0
305
1
306
14
307
1
308
1