en | System Event Timers
17.8

Codepad Lockout Time

Item
Codepad Lockout Time 0478
All codepads are locked out for the programmed time if an invalid code is entered more times
than allowed by the code retry attempts programmed in Location 424. If the Codepad Lockout
Time is programmed as 0, codepad lockout does not occur.
See also
17.9

Siren Run Time

Item
Siren Run Time
The Siren Run Time determines how long the horn speaker/siren operates during an alarm.
You can program the Siren Run Time from 0 to 15 min in 1-min intervals.
17.10

Siren Sound Rate

Item
Siren Sound Rate
The Siren Sound Rate varies the frequency of the siren tone slowest (0) and to fastest (15).
The Siren Sound Rate does not change the frequency of the fire alarm tone.
17.11

Auto Arming Pre-Alert Time

Item
Auto Arming Pre-Alert Time
This location sets the time period during which the control panel warns you it is automatically
armed in AWAY Mode. The codepad beeps once every second until the Pre-Alert Timer expires:
the system then automatically arms itself in AWAY Mode. If you want the system to
automatically arm in STAY Mode 1, enable Option 4 in Location 496 (refer to Consumer
Options 1, page 141).
After the control panel is automatically armed in AWAY Mode or STAY Mode 1, Exit Time starts.
If a valid User Code is entered during the Pre-Alert Time, the Auto Arming Time programmed in
Locations 482 to 485 is extended by 1 hour.
If you want a programmable output to operate during the Auto Arming Pre-Alert Time, use
Output Event Type 0,5 Auto Arm Pre-Arming Alert Time.
See also
2017.10 | 03 | F.01U.298.026
Location
Option
0 = No lockout
1 – 15 = Lockout time 10 – 150 sec.
(Increments of 10 sec.)
Access Denied, page 111
Location
Option
0479
0 = No Siren time
1 – 15 = Siren time 1 – 15 min. (increments of
1 min.)
Location
Option
0480
0 = Slowest frequency
15 = Fastest frequency
Location
0481
Auto Arming Time, page 137
Option
0 = No alert time
1 – 15 = Alert time 5 – 75 min.
(increments of 5 min.)