When you enter Installer's Programming Mode, you
are automatically positioned at Location 000, the first
digit of the Primary Telephone Number for
Receiver 1. The codepad indicators show the current
data stored in this location.
Table 34: Codepad Indicators
Data
Zone Indicators
Value
1
2
3
0
1
X
2
X
3
X
4
5
6
7
8
9
X
10
11
X
12
X
13
X
14
15
To move to a different programming location:
Enter the location number and press [AWAY].
For example, press [3 4][AWAY] to automatically
step you to the beginning of the Subscriber ID
Number for Receiver 1. The data stored in the new
location appears.
To move to the next location:
Press [AWAY].
For example, if you are currently positioned at
Location 034, press [AWAY] to step to Location 035.
To move to the previous location:
Press [STAY].
For example, if you are positioned at Location 035,
press [STAY] to step back to Location 034.
To change data in the current location:
Enter the new value (0 to 15) and press [STAY].
The data is stored and you remain positioned at the
same location. The new value is displayed using the
codepad indicators (for example, if you enter [1 4]
and press [STAY], the Zone 4 and MAINS indicators
are lit).
To exit from Installer's Programming Mode:
Enter command [9 6 0] and press [AWAY].
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns to the
disarmed state and is now ready for use.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
4
5
6
7
8
MAINS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Programming
Refer to Section 7.4 Installer's Programming Commands
on page 36 for more information about using
Installer's Programming Mode.
7.2
Programming with the
Programming Key
The CC891 Programming Key allows you to store or
copy programming information from your control
panel. After storing information in the programming
key, you can easily program other ICP-CC488
Control Panels with the same programming data.
You can also use the programming key to back up
existing information.
If you connect the programming key to the control
panel when it is disarmed, the key automatically
initiates a data transfer to the control panel's
memory.
If you have a new programming key, enter Installer's
Programming Mode, program the system as required,
and then connect the programming key to the
control panel.
To connect the programming key:
Locate the socket labeled PROGRAMMING KEY at
the top of the printed circuit board (PCB) next to the
Auxiliary Module socket (refer to Figure 24 on page
96). Observe the triangular markings on the PCB and
align them with the markings on the programming
key.
To copy data from the control panel data to the
programming key:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
2. Enter [9 6 2 #].
Refer to Section 7.4.4 Command 962 – Copy the
Control Panel Memory to the Programming Key on
page 37 for more information.
3. Enter [9 6 0 #] to exit from Installer's
Programming Mode.
Two beeps sound and the system returns to the
disarmed state. Before removing the
programming key, wait 2 sec for the activity
LED to return to its normal state. The
programming key becomes your standard data
pattern for future control panel programming.
If you enter Installer's Programming Mode, insert a
programming key, and then change the data in any
location, the data for both the programming key and
the control panel is changed at the same time.