Evaluate Start and Stop of CPU Modules
This section describes how to confirm the continuous system operation after stopping one of the
CPU modules.
1.
Confirm that the CPU modules are duplicated.
To check if the CPU modules are duplicated, see the status LEDs of the CPU modules.
[Indicat[Indications of status LEDs when CPU modules are duplicated]
1
CPU/IO module status LED1
2
CPU/IO module status LED2
3
DISK ACESSS LED
2.
Use the ft server utility to stop the operation of a CPU module to remove.
From [Start], select [All Programs], [NEC ESMPRO Agent] then [ft server utility] to start
the ft server utility. Then, from the ft server utility, select [CPU Module] then the CPU
module to stop (*) from the [FTSever] tree on the left pane, and click [Down] of [Bring
Up/Bring Down].
* As for the CPU module to stop, select [CPU Module(ID:0)] to stop CPU module 0, select
[CPU Module(ID:1)] to stop CPU module 1.
LED
Windows Setup and Operation 3-35
CPU module 0
(Operating)
-
Green
Green blinking
CPU module 1
(Operating)
-
Green
Green blinking