Evaluate Start And Stop Of Cpu Modules - NEC Express 5800 User Manual

Hide thumbs Also See for Express 5800:
Table of Contents

Advertisement

Evaluate Start and Stop of CPU Modules

This section describes how to confirm the continuous system operation after stopping one of the
CPU modules.
1.
Confirm that the CPU modules are duplicated.
To check if the CPU modules are duplicated, see the status LEDs of the CPU modules.
[Indications status LEDs when CPU modules are duplicated]
1
CPU module status LED1
2
CPU module status LED2
2.
Use the ft server utility to stop the operation of a CPU module to remove.
From [Start], select [All Programs], [NEC ESMPRO Agent] then [ft server utility] to start the
ft server utility. Then, from the ft server utility, select [CPU Module] then the CPU module to
stop from the [FTSever] tree on the left pane, and click [Down] of [Bring Up/Bring Down].
LED
Windows Setup and Operation
CPU module#1
(Operating)
-
Green
3-43
CPU module#2
(Operating)
-
Green

Advertisement

Table of Contents
loading

Table of Contents