Check and Clear of MTBF Information

The MTBF information of a component can be viewed or cleared (initialized).
NEC Express5800/320Fc series manages the MTBF (mean time between failure) of each component.
If a fault occurs in a component, the NEC Express5800/320Fc series calculates the MTBF of the
component again. If the calculated value is lower than the pre-defined threshold, the NEC
Express5800/320Fc series disables the component to be used.
Contact your maintenance personnel if such a symptom as above occurs.
IMPORTANT:A disabled component with the MTBF lower than the threshold can be
forcibly enabled by clearing the MTBF. However, contact your maintenance personnel for the
forced use of such a component.
To clear the MTBF information of a component with NEC ESMPRO Manager, use the
[Maintenance] tree of the component of the [ft] tree of the data viewer. Open the tree of the
component whose MTBF information is to be cleared and select the [Maintenance] tree.
To clear the MTBF information of a component with the ft server utility, use the utility screen of the
component. The table below shows the potential cases in which the MTBF information of a
component is to be cleared. Contact your maintenance personnel for clearing MTBF information.
Component
CPU Module
To start the module forcibly after
replacing a module or if MTBF
became lower than the threshold due
to malfunction and disabled the
module.
Executable in the following module
state (this can be viewed on manager
screen):
Broken
MTBF is lower than the threshold.
PCI Module
Same as above
Ethernet
To start the module/component forcibly
Adapter
after replacing a module or if MTBF
became lower than the threshold due
to malfunction and disabled the
module/component.
Executable in the following module
state (this can be viewed on manager
screen):
Broken
MTBF is lower than the threshold.
SCSI Adapter
IMPORTANT:You can also clear MTBF information for the PCI module, Ethernet Adapter and
SCSI Adapter by unplugging and plugging the live wire of the PCI module.
MTBF clear
Remote
Installing and Using Utilities 5-55
Local
To start the module forcibly after replacing
a module or if MTBF is lower than the
threshold due to malfunction and disabled
the module.
Executable in the following module state:
The amber LED is on.
The event indicating that MTBF is lower
than the threshold is registered in the
event log.
Same as above
To start the module/component forcibly
after replacing a module or if MTBF is
lower than the threshold due to
malfunction and disabled the
module/component.
Executable in the following module state
(this can be viewed on manager screen):
The amber LED is on.
The event indicating that MTBF is lower
than the threshold is registered in the
event log.