5-42 Installing and Using Utilities

Check and Clear of MTBF Information

The MTBF information of a component can be viewed or cleared (initialized).
NEC Express5800/ft series manages the MTBF (mean time between failure) of each component. If
a fault occurs in a component, the NEC Express5800/ft series calculates the MTBF of the
component again. If the calculated value is lower than the pre-defined threshold, the NEC
Express5800/ft series disables the component to be used.
Contact your maintenance personnel if such a symptom as above occurs.
The table below shows in which Fault Class a component can check.
Component
CPU Module
PCI Module
Remote:
Executable from remote management PC by using NEC ESMPRO Manager
Local:
Executable on local server by using ft server utility
–:
Not support
IMPORTANT: A disabled component with the MTBF lower than the threshold can be
forcibly enabled by clearing the MTBF. However, contact your maintenance personnel for the
forced use of such a component.
To clear the MTBF information of a component with NEC ESMPRO Manager, use the
[Maintenance] tree of the component of the [ft] tree of the DataViewer. Open the tree of the
component whose MTBF information is to be cleared and select the [Maintenance] tree.
To clear the MTBF information of a component with the ft server utility, use the utility screen of the
component. The table below shows the potential cases in which the MTBF information of a
component is to be cleared. Contact your maintenance personnel for clearing MTBF information.
Component
CPU Module
To start the module forcibly after
replacing a module or if MTBF became
lower than the threshold due to
malfunction and disabled the module.
Executable in the following module
state (this can be viewed on manager
screen):
Broken
MTBF is lower than the threshold.
PCI Module
Same as above
Remote:
Local:
–:
Check of MTBF Information
Remote
Fault Class:
uncorrectable
Fault Class:
uncorrectable
Remote
Executable from remote management PC by using NEC ESMPRO Manager
Executable on local server by using ft server utility
Not support
Local
Fault Class:
correctable
uncorrectable
*
microsync
* The current version
does not support it.
Fault Class:
uncorrectable
MTBF clear
To start the module forcibly after replacing
a module or if MTBF became lower than
the threshold due to malfunction and
disabled the module.
Executable in the following module state:
The amber LED is on.
The event indicating that MTBF is lower
than the threshold is registered in the
event log.
Same as above
Local

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

N8800-163fExp320lExp320mNec express5800 series

Table of Contents