Checking sensors on managed servers
You can check sensor data on managed servers using the show command with the /admin1/
system[n]/sensor[n] target.
To check sensor data on an managed server:
Enter the show command followed by the /admin1/system[n]/sensor[n] target.
/admin1-> show /system3/sensor1
/system3/sensor1
properties
172.26.25.122:AVCT_DiscreteSensor
verbs
subtargets
Checking fans on managed servers
You can check fan data on managed servers using the show command with the /admin1/system[n]/
fan[n] target.
To check fan data on an managed server:
Enter the show command followed by the /admin1/system[n]/fan[n] target.
/admin1-> show /system3/fan1
/system3/fan1
Chapter 8: Using SMASH Command Line Management
SystemName = 172.26.25.122
OperationalStatus =
RequestedState = 5 (No Change)
EnabledState = 5 (Not Applicable)
HealthState = 0 (Unknown)
ElementName = ROMB Battery
CurrentState = N/A
SensorType = 3 (Voltage)
PossibleStates =
CreationClassName = AVCT_DiscreteSensor
SystemCreationClassName =
DeviceID = 32:0:17