Chapter 9 Operation and Maintenance
9.4 Post Start-of-Operation Changes to the Configuration
9.4.3
Replacing SAS Cards
The following explains how to replace a failed SAS card.
Note that this is only an overview of the replacement procedure. Refer to the relevant manuals
for more details.
Refer
The procedure to replace a SAS card is as follows:
Procedure
1
2
2-1
2-2
3
3-1
3-2
4
User guide for SAS card
"ETERNUS Disk storage systems User's Guide -Server Connection-"
Before performing this procedure, use the ETERNUS DX60/DX80's GUI or CLI
to check the SAS address or host affinity of the SAS card that is to be replaced,
and record this setting for later replication.
Replace the server-side SAS card.
Turn off the server whose SAS card is to be replaced.
Replace the SAS card.
For details of the replacement procedure, refer to the user guide attached with the SAS
card.
Adjust the settings as necessary, using the ETERNUS DX60/DX80's GUI or CLI.
Delete the SAS address or host affinity setting assigned to the removed SAS card.
Referring to the information recorded in
affinity of the new SAS card in the ETERNUS DX60/DX80.
When the setting is complete, confirm that the server can access the ETERNUS
DX60/DX80.
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
Copyright 2011 FUJITSU LIMITED
Step
1, register the SAS address or host
207
End of procedure
P3AM-3042-08ENZ0