Chapter 5 Installation
5.2 Rack Installation
3
4
4-1
Install the AC outlet box in the rack.
Fasten it to the prepared holes in the pillars with eight M5 screws.
M5 screws
M5 screws
Attach the blank panel to the rack front.
Install it in the same position as the AC outlet box.
Attach the M5 cage nuts or M5 rack nuts to the front rack pillar.
-
Attachment positions
On either side, insert four M5 cage nuts or M5 rack nuts in the 2nd and 5th holes
above the blank panel base line.
M5 cage nut or
[Left]
M5 rack nut
5th position
2U
2nd position
-
Attachment procedure
M5 cage nut
Clip the cage nut tabs into the desired
hole from the inside.
Side view
M5 cage nut
Rack pillar (square)
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
Copyright 2011 FUJITSU LIMITED
(Rear rack pillars)
Use the M5 cage nuts if the rack pillar holes are square.
Use the M5 rack nuts if the rack pillar holes are round.
(Rear rack pillars)
[Right]
Blank panel
Base line of
AC outlet box
M5 rack nut
Clip the rack nut over the desired
hole from the side.
105
M5 cage nut or
M5 rack nut
5th position
2nd position
M5 Rack nut
Rack pillar (round)
P3AM-3042-08ENZ0