Powering On The Vls9000 Series System; Expansion Disk Array Rear Panel Led Status During Normal Operation - HP StorageWorks 9000 - Virtual Library System User Manual

Hp storageworks 9000-series virtual library system user guide (ag306-96027, march 2010)
Hide thumbs Also See for StorageWorks 9000 - Virtual Library System:
Table of Contents

Advertisement

Figure 40 Expansion disk array rear panel LED status during normal operation
.
Item
Location
1
Power module
2
3
4
Expansion controller
5
6

Powering on the VLS9000 series System

To power on the VLS9000 system:
1.
Power on the two private LAN switches connected to the VLS. (VLS9000 7.5 TB and 10 TB systems
only include one LAN switch.)
2.
Power on the two private Fibre Channel switches connected to the VLS. (VLS9000 7.5 TB and
10 TB systems do not include Fibre Channel switches.)
3.
Power on all arrays in the VLS. See
4.
Press the Power On/Standby button on all the secondary nodes.
5.
After the secondary nodes are powering up, press the primary node's Power On/Standby button.
136
Operation
LED
AC power good (green)
DC-Fan Fault/Service Required
(yellow)
SAS In port status (green)
Fault/Service Required (yellow)
Power On/OK (green)
SAS Out port status (green)
"Powering on VLS9000
Arrays" on page 133.
LED state
On
Off
On
Off
On
On

Hide quick links: