HP StorageWorks 9000 - Virtual Library System User Manual page 65

Hp storageworks 9000-series virtual library system user guide (ag306-96027, march 2010)
Hide thumbs Also See for StorageWorks 9000 - Virtual Library System:
Table of Contents

Advertisement

Fibre Channel Switch 4/16q #1
Item
Description
FC cable from port 3 of 7th node (if present), or FC port 0 of RAID controller 0 of 10th array
8
(if present)
FC cable from port 3 of 8th node (if present), or FC port 0 of RAID controller 0 of 9th array
9
(if present)
10—16
FC cable from FC port 0 of RAID controller 0, 2nd — 8th arrays (if present)
17
FC cable from FC port 0 of RAID controller 0 of 1st array (array 0)
18—21
Empty, or XPAK transponders from the interswitch link kit (if present)
Fibre Channel Switch 4/16q #2
Item
Description
1
Ethernet cable from port 23 of Ethernet Switch 2810 24G
2
FC cable from FC port 4 of primary node
3—7
FC cable from FC port 4 of 2nd — 6th nodes (if present)
FC cable from FC port 2 of 7th node (if present), or FC port 0, of RAID controller 1 of 10th
8
array (if present)
FC cable from FC port 2 of 8th node (if present), or FC port 0, of RAID controller 1 of 9th
9
array (if present)
10—16
FC cable from FC port 0 of RAID controller 1, 2nd — 8th arrays (if present)
17
FC cable from FC port 0 of RAID controller 1 of 1st array (array 0)
18—21
Empty, or XPAK transponders from the interswitch link kit (if present)
Locate 2 meter Fibre Channel cables from the array kit contents.
1.
Connect one end of a Fibre Channel cable to port 15 of Fibre Channel Switch 4/16q #1. Connect
the other end of the Fibre Channel cable to Fibre Channel port 0 of RAID controller 0 of the first
array (array 0).
2.
Connect one end of a Fibre Channel cable to port 15 of Fibre Channel Switch 4/16q #2. Connect
the other end of the Fibre Channel cable to Fibre Channel port 0 of RAID controller 1 of the first
array (array 0).
3.
With multiple arrays:
a.
Working backwards from the last Fibre Channel port on Fibre Channel switch #1, connect
one end of a Fibre Channel cable to the next available Fibre Channel port on Fibre Channel
switch #1. Connect the other end of the Fibre Channel cable to Fibre Channel port 0 of
RAID controller 0 of second array (array 1).
b.
Working backwards from the last Fibre Channel port on Fibre Channel switch #2, connect
one end of a Fibre Channel cable to the next available Fibre Channel port on Fibre Channel
switch #2. Connect the other end of the Fibre Channel cable to Fibre Channel port 0 of
RAID controller 1 of second array (array 1).
HP StorageWorks
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vls 9000

Table of Contents