4. Enable the FA-PWWN on the HBA. The following steps are to be executed on the server and not
Once the Brocade HBA has been assigned the FA-PWWN, the HBA retains the FA-PWWN until it is
rebooted. This means you cannot unplug and plug the cable into a different port on the switch. You
must reboot the HBA before moving the HBA to a different port. If you move an HBA to a different
port on a switch running Fabric OS v7.0.0 or later, the HBA will disable its port. If the HBA moves to
a different port on a switch running a version of Fabric OS earlier than 7.0.0, the HBA will continue
to disable its port.
Supported switches and configurations for FA-PWWN
The FA-PWWN feature is supported on the following platforms:
•
•
•
Fabric OS Administrator's Guide
53-1002446-01
the switch.
a. Log in to the server as root.
b. Enter the following command:
bcu port -faa port_id --enable
c.
Enter the following command:
bcu port -faa port_id --query
Switch platforms running Fabric OS v7.0.0 or later:
-
Brocade DCX, DCX-4S, and DCX 8510 family
-
Brocade 300
-
Brocade 5100
-
Brocade 5300
-
Brocade 6505
-
Brocade 6510
-
Brocade VA-40FC
Access Gateway platforms running Fabric OS v7.0.0 or later:
-
Brocade 300
-
Brocade 5100
-
Brocade 6510
Brocade HBAs with driver version 3.0.0.0:
-
Brocade 415
-
Brocade 425
-
Brocade 815
-
Brocade 825
Supported switches and configurations for FA-PWWN