20
End-to-end performance monitoring

Supported port configurations for EE monitors

You can configure EE monitors on F_Ports and, depending on the switch model, on E_Ports. The
following platforms support EE monitors on E_Ports:
Identical EE monitors cannot be added to the same port. Two EE monitors are considered identical
if they have the same SID and DID values after applying the end-to-end mask.
An EE monitor and a port Top Talker monitor cannot co-exist on the same port.
Co-existence of EE monitors and Top Talker monitors on ports belonging to the same ASIC is not
recommended because the statistics for the same flow going through ports on the same ASIC
might be inaccurate.

Adding EE monitors

1. Connect to the switch and log in using an account with admin permissions.
2. Enter the following command:
When you add an EE monitor to a port, specify the sourceID and destID in the ingress direction. For
example,
FIGURE 62
End-to-end performance monitoring looks at traffic on SID/DID pairs in any direction. That is, even
if the SID is for a remote device, the traffic is monitored in both directions (the Tx/Rx counters are
reversed).
Example of monitoring the traffic from Host A to Dev B
On Domain 1, add a monitor to the F_Port, as follows:
This monitor (Monitor 1) counts the frames that have an SID of 0x011200 and a DID of 0x021e00.
For Monitor 1, RX_COUNT is the number of words from Host A to Dev B, and TX_COUNT is the
number of words from Dev B to Host A.
402
Brocade 6505
Brocade 6510
Brocade DCX 8510 family
perfaddeemonitor [slotnumber/]portnumber sourceID destID
Figure 62
shows two devices:
Host A is connected to domain 1 (0x01), switch area ID 18 (0x12), AL_PA 0x00.
Dev B is a storage device connected to domain 2 (0x02), switch area ID 30 (0x1e), AL_PA
0x00.
Host A
F_Port
2
SID = 0x011200
Monitor 1
Setting end-to-end monitors on a port
switch:admin> perfaddeemonitor 2/2 "0x011200" "0x021e00"
E_Port
E_Port
13
3
Domain 1
Monitor 2
Monitor 3
Dev B
F_Port
14
Domain 2
DID = 0x021e00