HP SN3000B Administrator's Manual page 552

Brocade fabric os administrator's guide - supporting fabric os v7.0.1 (53-1002446-01, march 2012)
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

A
Fabric configurations for interconnectivity
3. Physically connect the configured FC router EX_Port to the M-EOS switch, and issue the
4. Start Brocade Network Advisor and select the fabric for the M-EOS switch.
5. View the fabric topology.
6. Log in to the Fabric OS edge fabric switch and enter the nsAllShow or the nsCamShow
514
switchShow command on the Brocade FC router.
New domains should be visible for each IFL (front domain) that connects the Fabric OS switch
to the FC router and one domain for the xlate domain.
New domains should be visible for each FC router connected to the M-EOS switch. Multiple
connections from the same FC router appear as only a single domain. New domains also
appear for every xlate domain that was created to import a remote device.
In Brocade Network Advisor, the M-EOS switch should appear green. Tab to Zone and verify
that the zone set configuration is correct: a blue icon beside each entry indicates that the
devices are logged in to the fabric.
command.
edgeswitch:admin> nsallshow
{
010e00 020000 03f001 04f002
4 Nx_Ports in the Fabric }
edgeswitch:admin> nscamshow
nscam show for remote switches:
Switch entry for 1
state
rev
owner
known
v520
0xfffc02
Device list: count 1
Type Pid
COS
N
010e00;
Fabric Port Name: 20:0e:00:60:69:e2:18:b6
Permanent Port Name: 10:00:00:00:00:01:00:00
Port Index: 14
Share Area: No
Device Shared in Other AD: No
Switch entry for 3
state
rev
owner
known
v410
0xfffc02
Device list: count 1
Type Pid
COS
N
03f001;
2,3;10:00:00:00:c9:44:54:04;20:00:00:00:c9:44:54:04;
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.92A2
Fabric Port Name: 50:00:51:e3:70:9a:3d:e8
Permanent Port Name: 10:00:00:00:c9:44:54:04
Port Index: na
Share Area: No
Device Shared in Other AD: No
Switch entry for 4
state
rev
owner
known
v410
0xfffc02
Device list: count 1
Type Pid
COS
N
04f002;
Fabric Port Name: 50:06:06:91:23:45:6a:13
PortName
3;10:00:00:00:00:01:00:00;10:00:00:00:00:00:01:00;
PortName
PortName
3;10:00:00:00:00:03:00:00;10:00:00:00:00:00:03:00;
NodeName
NodeName
DV5-5.10A10 "
NodeName
Fabric OS Administrator's Guide