HP SN3000B Administrator's Manual page 332

Brocade fabric os administrator's guide - supporting fabric os v7.0.1 (53-1002446-01, march 2012)
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

12
Setting up TI over FCR (sample procedure)
3. Log in to the edge fabric 2 and set up the TI zone.
E2switch:admin> fabricshow
Switch ID
-------------------------------------------------------------------------
1: fffc01 50:00:51:e3:95:36:7e:09
4: fffc04 50:00:51:e3:95:48:9f:a1
9: fffc09 10:00:00:05:1e:40:f0:7d
The Fabric has 3 switches
4. Log in to the backbone fabric and set up the TI zone.
294
a. Enter the fabricShow command to display the switches in the fabric. From the output, you
can determine the front and translate domains.
Worldwide Name
b. Enter the following commands to create and display a TI zone:
E2switch:admin> zone --create -t ti TI_Zone1 -p "9,2; 9,3; 9,6; 1,-1; 4,-1"
E2switch:admin> zone --show
Defined TI zone configuration:
TI Zone Name:
TI_Zone1
Port List:
9,2; 9,3; 9,6; 1,-1; 4,-1
Status: Activated
c.
Enter the following commands to reactivate your current effective configuration and
enforce the TI zones.
E2switch:admin> cfgactvshow
Effective configuration:
cfg:
cfg_TI
zone:
lsan_t_i_TI_Zone1
10:00:00:00:00:00:02:00:00
10:00:00:00:00:00:03:00:00
10:00:00:00:00:00:08:00:00
E2switch:admin> cfgenable cfg_TI
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
If the update includes changes to one or more traffic isolation zones, the
update may result in localized disruption to traffic on ports associated
with the traffic isolation zone changes
Do you want to enable 'cfg_TI' configuration
zone config "cfg_TI" is in effect
Updating flash ...
a. Enter the following commands to create and display a TI zone:
BB_DCX_1:admin> zone --create -t ti TI_Zone1 -p "1,9; 1,1; 2,4; 2,7;
10:00:00:00:00:08:00:00; 10:00:00:00:00:02:00:00; 10:00:00:00:00:03:00:00"
BB_DCX_1:admin> zone --show
Defined TI zone configuration:
TI Zone Name:
TI_Zone1
Port List:
1,9; 1,1; 2,4; 2,7; 10:00:00:00:00:08:00:00;
10:00:00:00:00:02:00:00; 10:00:00:00:00:03:00:00
Status: Activated
Enet IP Addr
0.0.0.0
0.0.0.0
10.32.72.9
Failover: Enabled
Failover: Enabled
FC IP Addr
Name
0.0.0.0
"fcr_fd_1"
0.0.0.0
"fcr_xd_6_9"
0.0.0.0
>"E2switch"
(yes, y, no, n): [no] y