Adding a Top Talker monitor to a port (port mode)

1. Connect to the switch and log in using an account with admin permissions.
2. Enter the perfTTmon

Adding Top Talker monitors on all switches in the fabric (fabric mode)

When fabric mode is enabled, you can no longer install Top Talker monitors on an F_Port unless you
delete fabric mode.
1. Connect to the switch and log in using an account with admin permissions.
2. Remove any EE monitors in the fabric, as described in
3. Enter the perfTTmon
4. Type y at the prompt to continue.
Displaying the top
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the perfTTmon
Fabric OS Administrator's Guide
53-1002446-01
add command.
--
perfttmon --add [egress | ingress] [slotnumber/]port
For example, to monitor the incoming traffic on port 7:
perfttmon --add ingress 7
To monitor the outgoing traffic on slot 2, port 4 on a Backbone:
perfttmon --add egress 2/4
Fabric mode Top Talker monitors and EE monitors cannot both exist in the fabric.
add fabricmode command.
--
perfttmon --add fabricmode
The system responds:
Before enabling fabric mode, please remove all EE monitors in the fabric
continue? (yes, y, no, n):
Top Talker monitors are added to E_Ports in the fabric and fabric mode is enabled. Any Top
Talker monitors that were already installed on F_Ports are automatically uninstalled.
If EE monitors are present on the local switch, the command fails with the message:
Cannot install Fabric Mode Top Talker because EE monitor is already present
If EE monitors are present on remote switches, the command succeeds; however, on the
remote switches, fabric mode fails and a raslog message is displayed on those switches.
If a new switch joins the fabric, you must run the perfTTmon
that switch. The Top Talker configuration information is not automatically propagated to the
new switch.
n
bandwidth-using flows on a port (port mode)
show command.
--
perfttmon --show [slotnumber/]port [n] [wwn | pid]
Top Talker monitors
"Deleting EE monitors"
on page 404.