HP SN3000B Administrator's Manual page 238

Brocade fabric os administrator's guide - supporting fabric os v7.0.1 (53-1002446-01, march 2012)
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

9
Firmware download on a Backbone
10. Optionally, after the failover, connect to the switch, and log in again as admin. Using a separate
200
If an AP blade is present: At the point of the failover an autoleveling process is activated.
Autoleveling is triggered when the active CP detects a blade that contains a different version of
the firmware, regardless of which version is older. Autoleveling downloads firmware to the AP
blade, swaps partitions, reboots the blade, and copies the new firmware from the primary
partition to the secondary partition. If you have multiple AP blades, they are updated
simultaneously; however, the downloads can occur at different rates.
Autoleveling takes place in parallel with the firmware download being performed on the CPs,
but does not impact performance. Fibre Channel traffic is not disrupted during autoleveling,
but GbE traffic on AP blades may be affected.
ecp:admin> firmwaredownload
Type of Firmware (FOS, SAS, or any application) [FOS]:
Server Name or IP Address: 10.1.2.3
User Name: userfoo
File Name: /home/userfoo/v7.0.0
Network Protocol (1-auto-select, 2-FTP, 3-SCP, 4-SFTP)) [1]:
Password: <hidden>
Checking version compatibility...
Version compatibility check passed.
The following AP blades are installed in the system.
Slot Name
Versions
-----------------------------------------------------------------
4
FR4-18i
v7.0.0
10
FR4-18i
v7.0.0
This command will upgrade the firmware on both CPs and all AP blade(s) above.
If you want to upgrade firmware on a single CP only, please use -s option.
You may run firmwaredownloadstatus to get the status of this"
command.
This command will cause a warm/non-disruptive boot on the active CP,
but will require that existing telnet, secure telnet or SSH sessions
be restarted.
Do you want to continue [Y]: y
The firmware is being downloaded to the Standby CP. It may take up to 10
minutes
session to connect to the switch, enter the firmwareDownloadStatus command to monitor the
firmware download status.
sw0:FID128:admin> firmwaredownloadstatus
[1]: Mon Mar 22 04:27:21 2010
Slot 7 (CP1, active): Firmware is being downloaded to the switch. This step
may take up to 30 minutes.
[2]: Mon Mar 22 04:34:58 2010
Slot 7 (CP1, active): Relocating an internal firmware image on the CP blade.
[3]: Mon Mar 22 04:35:29 2010
Slot 7 (CP1, active): The internal firmware image is relocated successfully.
[4]: Mon Mar 22 04:35:30 2010
Traffic Disrupted
None
None
Fabric OS Administrator's Guide