Configuring Flogi-Time Handling Of Duplicate Pwwn - HP SN3000B Administrator's Manual

Brocade fabric os administrator's guide - supporting fabric os v7.0.1 (53-1002446-01, march 2012)
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

3

Configuring FLOGI-time handling of duplicate PWWN

4. Enter the auditCfg
5. Issue the auditDump -s command to confirm that the audit messages are being generated.
Example of the syslog (system message log) output for audit logging

Configuring FLOGI-time handling of duplicate PWWN

Fabric OS has two configurable options for handling duplicate PWWN conflicts occurring on the
same switch.
Table 8
TABLE 8
Input port
FLOGI
received
FDISC
received
60
show command to view the filter configuration and confirm that the
--
correct event classes are being audited, and the correct filter state appears (enabled or
disabled).
switch:admin> auditcfg --show
Audit filter is enabled.
2-SECURITY
4-FIRMWARE
Oct 10 08:52:06 10.3.220.7 raslogd: AUDIT, 2008/10/10-08:20:19 (GMT),
[SEC-3020], INFO, SECURITY, admin/admin/10.3.220.13/telnet/CLI,
ad_0/ras007/FID 128, , Event: login, Status: success, Info: Successful login
attempt via REMOTE, IP Addr: 10.3.220.13.
Oct 10 08:52:23 10.3.220.7 raslogd: 2008/10/10-08:20:36, [CONF-1001], 13, WWN
10:00:00:05:1e:34:02:0c | FID 128, INFO, ras007, configUpload completed
successfully. All config parameters are uploaded.
Oct 10 09:00:04 10.3.220.7 raslogd: AUDIT, 2008/10/10-08:28:16 (GMT),
[SEC-3021], INFO, SECURITY, admin/NONE/10.3.220.13/None/CLI, None/ras007/FID
128, , Event: login, Status: failed, Info: Failed login attempt via REMOTE, IP
Addr: 10.3.220.13.
Existing login takes precedence over second login (default behavior).
Second login overrides existing login (optional behavior).
shows details of the default behavior.
Duplicate PWWN behavior: Existing login takes precedence over second login
Duplicate found on
same F_Port
1
Implicit logout.
2
Send FLOGI ACC.
N/A
Table 9
shows details of the optional behavior.
Duplicate found on different
Duplicate found on same
F_Port
NPIV port
1
Send FLOGI RJT.
N/A
2
RASLog Duplicate
Found.
3
Persistently disable
input port.
1
Send FDISC RJT.
Send FDISC ACC with
previously assigned
2
RASLog Duplicate
PID.
Found.
Duplicate found on
different NPIV port
1
Send FLOGI RJT.
2
RASLog Duplicate
Found.
3
Persistently
disable input port.
1
Send FDISC RJT.
2
RASLog Duplicate
Found.
Fabric OS Administrator's Guide
53-1002446-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.1

Table of Contents