Delta BLD-E1 Series User Manual page 96

Brushless motor dc drive
Table of Contents

Advertisement

Settings
Functions
0
No Function
1
AC Drive Operational
2
Operation speed attained
Desired Frequency
3
Attained 1 (Pr.02-25, 02-
26)
Desired Frequency
4
Attained 2 (Pr.02-27, 02-
28)
Zero Speed (frequency
5
command)
Zero Speed with Stop
6
(frequency command)
7
Over Torque (OT1)
8
Over Torque (OT2)
9
Drive Ready
User-defined Low-
10
voltage Detection
11
Malfunction Indication
12
Reserved
13
Overheat (Pr.06-14)
14~16 Reserved
17
Malfunction indication 1
18~19 Reserved
20
Warning Output
21
Over-voltage Warning
Revision May 2009, 00DE, V0.50
Active when there is an output from the drive or RUN
command is ON.
Active when the brushless DC motor drive reaches the output
frequency setting.
Active when the desired frequency (Pr.02-25, 02-26) is
attained.
Active when the desired frequency (Pr.02-27, 02-28) is
attained.
Active when frequency command =0. (the drive should be at
RUN mode)
Active when frequency command =0 or stop.
Active when detecting over-torque. Refer to Pr.06-05 (over-
torque detection selection-OT1), Pr.06-06 (over-torque
detection level-OT1) and Pr.06-07 (over-torque detection
time-OT1). (Pr.06-05~06-07)
Active when detecting over-torque. Refer to Pr.06-08 (over-
torque detection selection-OT2), Pr.06-09 (over-torque
detection level-OT2) and Pr.06-10 (over-torque detection
time-OT2). (Pr.06-08~06-10)
Active when the drive is ON and no abnormality detected.
Active when the DC Bus voltage is too low. (refer to Pr.06-00
low voltage level)
Active when fault occurs (except Lv stop).
Active when IGBT or heat sink overheats to prevent OH turn
off the drive. (refer to Pr.06-14)
Activate after 10ms when fault occurs (except Lv stop).
Active when the warning is detected.
Active when the over-voltage is detected.
Chapter 4 Parameters| BLD-E1 Series
Descriptions
4-55