Delta BLD-E1 Series User Manual page 75

Brushless motor dc drive
Table of Contents

Advertisement

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Parameter Reset
00-02
Control
VF
VFPG
mode
Settings
10 All parameters are reset to factory settings
When it is set to 10, all parameters will be reset to factory settings.
Start-up Display Selection
00-03
Control
VF
VFPG
mode
Settings 0
1
2
3
4
5
This parameter determines the start-up display page after power is applied to the drive. User
defined options are displayed according to Pr.00-04.
Content of Multi-Function Display
00-04
Control
VF
VFPG
mode
Settings
4-34
FOCPM
0
No Function
FOCPM
Display the frequency command value. (F)
Display the actual output frequency (H)
DC BUS voltage (V)
Display the output current (A)
Output voltage (E)
Multifunction display, see Pr.00-04
FOCPM
0 Display the output current in A supplied to the motor
1 Reserved
2 Display actual output frequency (H)
Display the actual DC BUS voltage in VDC of the
3
brushless DC motor drive (U)
Display the output voltage in VAC of terminals U, V,
4
W to the motor (E)
Display the power factor angle in º of terminals U, V,
5
W to the motor (n.)
Display the output power in kW of terminals U, V
6
and W to the motor (kW)
Display the actual motor speed in rpm (enabled
7
when using with PG card).
Display the estimated value of torque in % as it
8
relates to current.
9 Display PG position
Factory setting: 0
Factory setting: 0
Factory setting: 0
Revision May 2009, 00DE, V0.50