Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
1st Output
Voltage Setting 1
2nd Output
Voltage Setting 1
01-04
3rd Output
Voltage Setting 1
01-06
4th Output
Voltage Setting 1
01-08
Start Frequency
01-09
Control
VF
VFPG
mode
Settings
To distinguish which frequency should be start frequency, it needs to compare the value of
min. output frequency and start frequency. The larger value will be start frequency.
When min. output frequency > start frequency
min. output
frequency
start frequency
Output Frequency Upper Limit
01-10
Control
VF
VFPG
mode
Settings
Output Frequency Lower Limit
01-11
Control
VF
VFPG
mode
Settings
The upper/lower output frequency setting is used to limit the actual output frequency. If the
frequency setting is lower than the start-up frequency, it will run with zero speed. If the
frequency setting is higher than the upper limit, it will runs with the upper limit frequency. If
output frequency lower limit > output frequency upper limit, this function is invalid.
4-44
Voltage
Output Frequency
01-11
Lower Limit
01-02
Frequency output
ranges limitation
01-07
01-09
4th Freq.
3rd Freq.
Start Freq.
V/f Curve
0.00~400.00Hz
FOCPM
0.00~4800rpm
FOCPM
0.00~4800rpm
Output Frequency
Upper Limit
01-10
01-05
01-03
01-01
1st Freq.
2nd Freq.
When start frequency > min. output frequency
start frequency
min. output
frequency
Regular V/f Curve
Special V/f Curve
Frequency
01-00
Maximum Output
Frequency
Factory setting: 6
Factory setting: 3000
Factory setting: 0.00
Revision May 2009, 00DE, V0.50