Chapter 2 Installation and Wiring| BLD-E1 Series

2.4 Control Terminals

Specification
Terminal A, B
Terminal symbols and functions
Terminal
Terminal Function
Symbol
MI1
Forward-Stop command
MI2
Reverse-Stop command
MI3
Multi-function Input 3
MI4
Multi-function Input 4
MI5
Multi-function Input 5
MI6
Multi-function Input 6
2-10
Torque
2 kgf-cm (2 in-lbf)
Factory Settings (NPN mode)
ON:
forward running
OFF:
Ramp to stop
ON:
reverse running
OFF:
Ramp to stop
Refer to Pr.04-05 to Pr.04-08 for programming the
Multi-function Inputs.
ON: the activation current is 16mA.
OFF: leakage current tolerance is 10μA.
Wire
16-24 AWG (1.3-0.2mm
ON: Connect to DCM