Delta BLD-E1 Series User Manual page 161

Brushless motor dc drive
Table of Contents

Advertisement

Chapter 6 Fault Code Information and Maintenance| BLD-E1 Series
Fault
Fault Descriptions
Name
IGBT overheating
IGBT temperature exceeds
protection level
1 to 30HP: 100
IGBT overheating
Overload
The brushless DC motor drive
detects excessive drive output
current.
NOTE: The brushless DC
motor drive can withstand up
to 150% of the rated current
for a maximum of 60 seconds.
Motor 1 overload
Electronic Thermal Relay 1
Protection
Electronic Thermal Relay 2
Protection
6-4
1.
o
C
2.
3.
4.
5.
Return to the factory
1.
2.
1.
2.
3.
1.
2.
3.
4.
1.
2.
3.
4.
Corrective Actions
Ensure that the ambient temperature falls
within the specified temperature range.
Make sure that the ventilation holes are not
obstructed.
Remove any objects from the heatsinks and
check for possible dirty heat sink fins.
Check the fan and clean it.
Provide enough spacing for adequate
ventilation.
Check whether the motor is overloaded.
Take the next higher power brushless DC
motor drive model.
Check whether the motor is overloaded.
Check whether the rated current of motor
(Pr.05-01) is suitable
Take the next higher power brushless DC
motor drive model.
Check whether the motor is overloaded.
Check whether motor rated current setting
(Pr.05-01) is suitable
Check electronic thermal relay function
(Pr.06-05~ Pr.06-07)
Take the next higher power brushless DC
motor drive model.
Check whether the motor is overloaded.
Check whether motor rated current setting
(Pr.05-01) is suitable
Check electronic thermal relay function
(Pr.06-05~ Pr.06-07)
Take the next higher power brushless DC
motor drive model.
Revision May 2009, 00DE, V0.50

Advertisement

Table of Contents
loading

Table of Contents