Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Emergency Stop (EF) & Forced Stop Selection
07-28
Control
VF
VFPG
mode
Settings
When the multi-function input terminal is set to 10 or 14 and it is ON, the brushless DC motor
drive will be operated by Pr.07-28.
Time for Decreasing Torque at Stop
07-29
Control
FOCPM
mode
Settings
When the drive stop output it will produce the noise from the reacting force between the motor
and the mechanical brake. This parameter can be used to decrease this reacting force and
lower the noise.
It is used to set the time for decreasing torque to 0%.
RUN/STOP
4-76
FOCPM
0
Coast to stop
1
By deceleration Time 1
2
By deceleration Time 2
3
By deceleration Time 3
4
By deceleration Time 4
5
By Pr.01-31
0.000 to 1.000 sec
t
i
00-01
i
0%
Factory Setting: 0
Factory Setting: 0.000
100%
x
x (07-29)=t
300%
Revision May 2009, 00DE, V0.50