Delta BLD-E1 Series User Manual page 93

Brushless motor dc drive
Table of Contents

Advertisement

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Settings
27
ASR1/ASR2 selection
Emergency stop (EF1)
28
(Motor coasts to stop)
29-30
Reserved
31
High torque bias
32
Middle torque bias
33
Low torque bias
34-37
Reserved
Disable write EEPROM
38
function
39
Reserved
40
Enable drive function
Reserved
02-05
Reserved
02-06
Reserved
02-07
Reserved
02-08
4-52
Functions
ON: speed will be adjusted by ASR 2 setting.
OFF: speed will be adjusted by ASR 1 setting.
When it is ON, the drive will execute emergency stop
with fault code 50 (EF1)
When Pr.07-19 is set to 3:
31: The high torque bias is according to the Pr.07-21
setting.
32: The middle torque bias is according to the Pr.07-22
setting.
33: The low torque bias is according to the Pr.07-23
setting.
When this function is enabled, you can't write into
EEPROM.
When this function is enabled, the drive function can be
executed. This function can be used with multi-function
output (setting Pr.02-11~Pr.02-14 to 15) and (Pr.02-31
and Pr.02-32).
Descriptions
31
32
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
33
Torque Bias
OFF
No
ON
07-23
OFF
07-22
ON
07-23+07-22
OFF
07-21
ON
07-21+07-23
OFF
07-21+07-22
ON
07-21+07-22+07-23
Revision May 2009, 00DE, V0.50