Reset; Maintenance And Inspections - Delta BLD-E1 Series User Manual

Brushless motor dc drive
Table of Contents

Advertisement

Fault
Fault Descriptions
Name
Keypad communication
time-out

6.1.2 Reset

There are three methods to reset the brushless DC motor drive after solving the fault:
1.
Press STOP/RESET key on keypad.
2.
Set external terminal to "RESET" and then set to be ON.
3.
Send "RESET" command by communication.
NOTE
Make sure that RUN command or signal is OFF before executing RESET to prevent damage or
personal injury due to immediate operation.

6.2 Maintenance and Inspections

Before the check-up, always turn off the power and remove the cover. Wait at least 10 minutes after
all display lamps have gone out, and then confirm that the capacitors have fully discharged by
measuring the voltage between
Ambient environment
Check Items
Check the ambient temperature,
humidity, vibration and see if
there are any dust, gas, oil or
water drops
Check if there are any
dangerous objects in the
environment
Revision May 2009, 00DE, V0.50
Chapter 6 Fault Code Information and Maintenance| BLD-E1 Series
1.
Check if the wiring for the communication is
correct.
2.
Check if there is any wrong with the keypad.
~
. It should be less than 25VDC.
Methods and Criterion
Visual inspection and measurement
with equipment with standard
specification
Visual inspection
Corrective Actions
Daily
Maintenance
Period
Half
One
Year
Year
6-7