Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Sixth Most Recent Fault Time of Motor Operation (day)
12-29
Control
VF
VFPG
mode
Setting
No Factory Setting
12-30
No Factory Setting
12-31
12-00
User-defined Parameters
|
12-31
Control
VF
VFPG
mode
Settings
Users can enter the parameters from group 0 to group 11 into group 12 (it can save 32
parameters). The saved value can also be the parameter addresses (but the hexadecimal
value needs to be converted to decimal value).
The setting method of 211BH
Convert 211BH (hexadecimal) to decimal value:
2 1 1 B
1
1
x16 +
11
x16 =16+11=
4-104
FOCPM
0643
FOCPM
-
0
input
27
2127
Factory Setting: #.##
Factory Setting: -
Revision May 2009, 00DE, V0.50