Parameter
Explanation
02.12
Reserved
02.13
Multi-function
Output (MO1)
02.14
Multi-function
Output (MO2)
4-10
Settings
0:No function
1: Operation indication
2: Operation speed attained
3:Desired frequency
attained 1 (Pr. 02-25, 02-
26)
4:Desired frequency
attained 2 (Pr. 02-27, 02-
28)
5: Zero speed (frequency
command)
6: Zero speed with stop
(frequency command)
7: Over torque (OT1) (Pr.
06-05~06-07)
8: Over torque (OT2) (Pr.
06-08~06-10)
9: Drive ready
10:Low-voltage Detection
(LV)
11:Malfunction indication
12:Reserved
13:Overheat warning (Pr.
06-14)
21:Ove voltage warning
22:Over-current stall
prevention warning
23:Over-voltage stall
prevention warning
24:Drive operation mode
(Parameter: 00.21=0)
Factory
VF
VFPG
Setting
41
41