Delta BLD-E1 Series User Manual page 63

Brushless motor dc drive
Table of Contents

Advertisement

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Group 08 PM Parameters
Parameter
Explanation
08.00
Motor Auto
Tuning
08.01
Full-load Current
of Motor
08.02
Rated power of
Motor
08.03
Rated speed of
Motor (rpm)
08.04
Number of Motor
Poles
08.05
Rs of Motor
08.06
Reserved
08.07
Lq of Motor
08.08
Back
Electromotive
Force
08.09
Angle between
Magnetic Pole
and PG Origin
08.10
Magnetic Pole
Re-orientation
4-22
Settings
0: No function
1: Only for the unloaded motor, auto
measure the angle between
magnetic pole and PG origin (Pr.
08.09)
2: For PM parameters
3: Auto measure the angle between
magnetic pole and PG origin
(Pr.08-09)
40~120%)*00.01 Amps
0.00~655.35kW
0~65535
2~96
0.000~65.535Ω
0.0~6553.5mH
0.0~6553.5Vrms
0.0~360.0°
0: Disable
1: Enable
: The parameter can be set during operation.
Factory
Setting
0
#.##
#.##
200
10
#
#
#
360.0
0
Revision May 2009, 00DE, V0.50
VF VFPG FOCPM

Advertisement

Table of Contents
loading

Table of Contents