Delta BLD-E1 Series User Manual page 114

Brushless motor dc drive
Table of Contents

Advertisement

Run /Stop
DC Brake Proportional Gain
07-06
Control
VF
VFPG
mode
Settings
It is used to set the output voltage gain when brushless DC brake.
Reserved
07-07
Reserved
07-08
Reserved
07-09
Reserved
07-10
Fan Control
07-11
Control
VF
VFPG
mode
Settings
This parameter is used for the fan control.
When setting to 3, fan will start to run until temperature is less than 40°C if temperature
exceeds 40°C.
Reserved
07-12
Reserved
07-13
Revision May 2009, 00DE, V0.50
Output freque ncy
01-09
Start
frequen cy
07-0 3
ON
1 to 500Hz
FOCPM
0
Fan always ON
1
1 minute after DC brushless motor drive stops, fan will be OFF
2
Brushless DC motor drive runs and fan ON, brushless DC motor
drive stops and fan OFF
3
Fan ON to run when preliminary heat sink temperature attained
4
Fan always OFF
Chapter 4 Parameters| BLD-E1 Series
DC Brake Time
07-05
during St opping
Start-point for
DC brake
time during
stopping
OFF
DC Brake Time
07-0 4
Time
Factory Setting: 50
Factory Setting: 1
4-73