Delta BLD-E1 Series User Manual page 86

Brushless motor dc drive
Table of Contents

Advertisement

Accel. Time 1
01-12
Accel. Time 2
01-14
Accel. Time 3
01-16
Accel. Time 4
01-18
Control
VF
VFPG
mode
Settings
Decel. Time 1
01-13
Decel. Time 2
01-15
Decel. Time 3
01-17
Decel. Time 4
01-19
Control
VF
VFPG
mode
Settings
The Acceleration Time is used to determine the time required for the brushless DC motor
drive to ramp from 0Hz to Maximum Output Frequency (Pr.01-00).
The Deceleration Time is used to determine the time require for the brushless DC motor drive
to decelerate from the Maximum Output Frequency (Pr.01-00) down to 0Hz.
The Acceleration/Deceleration Time 1, 2, 3, 4 are selected according to the Multi-function
Input Terminals settings. The factory settings are acceleration time 1 and deceleration time 1.
The larger against torque and inertia torque of the load and the accel./decel. time setting is
less than the necessary value, it will enable torque limit and stall prevention function. When it
happens, actual accel./decel. time will be longer than the action above.
Reserved
01-20
Reserved
0-21
Reserved
0-22
Revision May 2009, 00DE, V0.50
FOCPM
0.00~600.00 sec
FOCPM
0.00~600.00 sec
Frequency
01-00
Max. Output
Frequency
Frequency
Setting
accel. time
01-12,14,16,18
Chapter 4 Parameters| BLD-E1 Series
decel. time
01-13,15,17,19
Accel./Decel. Time
Factory setting: 3.00
Factory setting: 3.00
Factory setting: 3.00
Factory setting: 3.00
Factory setting: 2.00
Factory setting: 2.00
Factory setting: 2.00
Factory setting: 2.00
Time
4-45