Exception code
LRC CHK Low
LRC CHK High
END 1
END 0
The explanation of exception codes:
Exception
code
01
02
03
04
10
Response Delay Time
09-05
Control
VF
VFPG
mode
Settings
This parameter is the response delay time after AC drive receives communication command
as shown in the following.
RS-485 BUS
Revision May 2009, 00DE, V0.50
'0'
'2'
'7'
'7'
CR
LF
Explanation
Illegal function code:
The function code received in the command message is not
available for the brushless DC motor drive.
Illegal data address:
The data address received in the command message is not
available for the brushless DC motor drive.
Illegal data value:
The data value received in the command message is not available
for the brushless DC motor drive.
Slave device failure:
The brushless DC motor drive is unable to perform the requested
action.
Communication time-out:
If Pr.09-03 is not equal to 0.0, Pr.09-02=0~1, and there is no
communication on the bus during the Time Out detection period (set
by Pr.09-03), "cE10" will be shown on the keypad.
FOCPM
0.0 ~ 200.0 ms
PC or PLC command
Handling time
of the AC drive
Chapter 4 Parameters| BLD-E1 Series
Response Message
of the AC Drive
Response Delay Time
Factory Setting: 2.0
4-91