Delta BLD-E1 Series User Manual page 92

Brushless motor dc drive
Table of Contents

Advertisement

Settings
st
The 1
8
or deceleration time
selection
rd
The 3
9
or deceleration time
selection
10
EF Input
11
Reserved
12
Stop output
13-14
Reserved
Operation speed
15
command form VR
Operation speed
16
command form ACI
Operation speed
17
command form AVI
18
Emergency Stop
19-26
Reserved
Revision May 2009, 00DE, V0.50
Functions
The acceleration/deceleration time of the drive could
be selected from this function or the digital statuses of
the terminals; there are 4 acceleration/deceleration
speeds in total for selection.
nd
, 2
acceleration
th
, 4
acceleration
If the drive receives STOP command, it will decelerate
to stop by Pr.01-31.
External fault input terminal and decelerates by Pr.07-
28. (EF fault will be recorded)
When this function is enabled, the drive output will stop
immediately and the motor is free run. When this
function is disabled, the drive will accelerate to the
frequency setting.
When the source of operation speed command is set to
VR, ACI and AVI at the same time and two or above
terminals are ON, the priority is VR>ACI>AVI.
When this function is enabled, the source of the
frequency will force to be VR.
When this function is enabled, the source of the
frequency will force to be ACI.
When this function is enabled, the source of the
frequency will force to be AVI.
When this function is enabled, the drive will ramp to stop
by Pr.07-28 setting.
Descriptions
Bit 0
Bit
Descriptions
1
0
0
First acceleration/deceleration
time
When output frequency is less
than Pr.01-23 (Switch
Frequency between 1st/4th
Accel/decel), it will output 4
accel/decel time.
nd
0
1
2
rd
1
0
3
accel./decel. time
th
1
1
4
accel./decel. time
Chapter 4 Parameters| BLD-E1 Series
accel./decel. time
th
4-51

Advertisement

Table of Contents
loading

Table of Contents