Trial Run - Delta BLD-E1 Series User Manual

Brushless motor dc drive
Table of Contents

Advertisement

Chapter 3 Keypad and Start Up| BLD-E1 Series

3.3 Trial Run

The factory setting of trial run is by the potentiometer, please operate by the following steps.
1.
After applying the power, setting the parameter according to the motor type in
parameter group 08. (For Delta's ECMD-E9 Series of motor, the drive will atuo set the
motor parameter to the default value)
2.
Please execute angle detection for the first time operation of Delta ECMD-E9 Motor
and drive. First set 08-00=1 and press RUN, the keypad will show "tun" during the
angle detection. The keypad will return to the main menu after the auto-detection is
finished.
3.
Verify that LED display shows 0~3000RPM (depends on the potentiometer position)
with RPM signal blinking and FWD indicator lighted on.
4.
Please set potentiometer to a low running speed around 100RPM.
5.
Press RUN key for forward running. For ramp to stop, please press STOP/RESET key.
6.
To switch to reverse running, press the MODE key and look for FWD page, then press
UP/DOWN key to REV page to finish setting.
7.
Check following items:
If the results of trial run are normal, please start the formal run.
3-8
Check if the direction of motor rotation is correct.
Check if the motor runs steadily without abnormal noise and vibration.
Check if acceleration and deceleration are smooth.
Revision May 2009, 00DE, V0.50

Advertisement

Table of Contents
loading

Table of Contents