Delta BLD-E1 Series User Manual page 107

Brushless motor dc drive
Table of Contents

Advertisement

Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
It is used to set the accel./decel. time selection when stall prevention occurs at constant
speed.
Over-torque Detection Selection (OT1)
06-05
Control
VF
VFPG
mode
Settings
Over-torque Detection Level (OT1)
06-06
Control
VF
VFPG
mode
Settings
Over-torque Detection Time (OT1)
06-07
Control
VF
VFPG
mode
Settings
Over-torque Detection Selection (OT2)
06-08
Control
VF
VFPG
mode
Settings
Over-torque Detection Level (OT2)
06-09
Control
VF
VFPG
mode
Settings
4-66
FOCPM
0
Over-Torque detection disabled.
1
Over-torque detection during constant speed operation, continue to
operate after detection
2
Over-torque detection during constant speed operation, stop
operation after detection
3
Over-torque detection during operation, continue to operate after
detection
4
Over-torque detection during operation, stop operation after
detection
FOCPM
10 to 250%
FOCPM
0.0 to 60.0 sec
FOCPM
0
Over-Torque detection disabled.
1
Over-torque detection during constant speed operation, continue to
operate after detection
2
Over-torque detection during constant speed operation, stop
operation after detection
3
Over-torque detection during operation, continue to operate after
detection
4
Over-torque detection during operation, stop operation after
detection
FOCPM
10 to 250%
Factory setting: 0
Factory setting: 150
Factory setting: 0.1
Factory setting: 0
Factory setting: 150
Revision May 2009, 00DE, V0.50