Terminal
Terminal Function
Symbol
+24V
DC Voltage Source
DCM
Digital Signal Common
HU/U
Reserved
HV/V
Reserved
HW/W
Reserved
A
PG feedback signal contact 1
B
PG feedback signal contact 2
PG feedback signal contact
Z/PWM
PWM
SPO
Reserved
+5V
Encoder Power Supply
GND
Feedback Signal Common
Multi-function Output 1
(Photocoupler)
MO1
Multi-function Output 2
(Photocoupler)
MO2
Multi-function output common
MCM
(Photocoupler)
+10V
Potentiometer power supply
Revision May 2009, 00DE, V0.50
Chapter 2 Installation and Wiring| BLD-E1 Series
Factory Settings (NPN mode)
ON: Connect to DCM
+24VDC, 20mA
Common for digital inputs
Sending PG signals to the drive, e.g. activation,
operation, speed control etc.
Sending PG signals to the drive, e.g. activation,
operation, speed control etc.
Sending PMW signals to the drive to activate at
the origin position.
The brushless DC motor monitors all kinds of
signal, such as during operation, speed attained
and overload indication, by the open collector
output. Please refer to Pr.02-13, Pr.02-14 for more
details.
+5V
internal circuit
Max 48Vdc 50mA
Power supply for analog frequency setting +10VDC
3mA (variable resistor 3~5kΩ)
Max:
48VDC/50mA
MCM
2-11