Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Group 11 Advanced Parameters
System Control
11-00
Control
VF
FOCPG FOCPM
mode
Settings
Reserved
11-01
Reserved
11-02
Reserved
11-03
Reserved
11-04
Reserved
11-05
Zero-speed Bandwidth
11-06
Control
FOCPM
mode
Settings
Low-speed Bandwidth
11-07
Control
FOCPM
mode
Settings
High-speed Bandwidth
11-08
Control
FOCPM
mode
Settings
After estimating inertia and set Pr.11-00=1 (auto tuning), user can adjust parameters Pr.11-06,
11-07 and 11-08 separately by speed response. The larger number you set, the faster
response you will get. Pr.10-08 is the switch frequency for low-speed/high-speed bandwidth.
Reserved
11-09
Reserved
11-10
Reserved
11-11
Reserved
11-12
Reserved
11-13
4-98
When position control is enabled, it doesn't need to set Pr.07-02
Bit 7=1
(DC Brake Current Level)
when power is applied, it will detect the position of magnetic pole
Bit 15=0
again
0 to 40Hz
0 to 40 Hz
0 to 40Hz
This parameter can be set during operation.
Revision May 2009, 00DE, V0.50
Factory Setting: 0
Factory Setting: 10
Factory Setting: 10
Factory Setting: 10