Delta BLD-E1 Series User Manual page 84

Brushless motor dc drive
Table of Contents

Advertisement

2nd Output Frequency Setting
01-03
Control
VF
VFPG
mode
Settings
2nd Output Voltage Setting
01-04
Control
VF
VFPG
mode
Settings
3rd Output Frequency Setting
01-05
Control
VF
VFPG
mode
Settings
3rd Output Voltage Setting
01-06
Control
VF
VFPG
mode
Settings
4th Output Frequency Setting
01-07
Control
VF
VFPG
mode
Settings
4th Output Voltage Setting
01-08
Control
VF
VFPG
mode
Settings
V/f curve setting is usually set by the motor's allowable loading characteristics. Pay special
attention to the motor's heat dissipation, dynamic balance, and bearing lubricity, if the loading
characteristics exceed the loading limit of the motor.
For the V/f curve setting, it should be Pr.01-01≥ Pr.01-03≥ Pr.01-05≥ Pr.01-07. There is no
limit for the voltage setting, but a high voltage at the low frequency may cause motor damage,
overheat, stall prevention or over-current protection. Therefore, please use the low voltage at
the low frequency to prevent motor damage.
V/F curve would only function as Pr. 00-09= 0 or 1 (under V/F control mode) and Pr. 00-10=0.
Revision May 2009, 00DE, V0.50
0.00~400.00Hz
230V series
0.1 to 255.0V
460V series
0.1 to 510.0V
0.00~400.00Hz
230V series
0.1 to 255.0V
460V series
0.1 to 510.0V
0.00~400.00Hz
230V series
0.1 to 255.0V
460V series
0.1 to 510.0V
Chapter 4 Parameters| BLD-E1 Series
Factory setting: 0.50
Factory Setting: 5.0
Factory Setting: 10.0
Factory setting: 0.50
Factory Setting: 5.0
Factory Setting: 10.0
Factory Setting: 0
Factory Setting: 0.0
Factory Setting: 0.0
4-43

Advertisement

Table of Contents
loading

Table of Contents