Parameter
Explanation
10.09
Encoder Stall and Slip
Error Treatment
10.10
Mode Selection for
UVW Input
10.11
ASR (Auto Speed
Regulation) Control
(P) of Zero Speed
10.12
ASR (Auto Speed
Regulation) Control (I)
of Zero Speed
10.13
ASR (Auto Speed
Regulation) Control
(P) 1
10.14
ASR (Auto Speed
Regulation) Control (I)
1
10.15
ASR (Auto Speed
Regulation) Control
(P) 2
10.16
ASR (Auto Speed
Regulation) Control (I)
2
10.17
ASR 1/ASR2 Switch
Frequency
10.18
ASR Primary Low
Pass Filter Gain
10.19
Zero Speed Gain (P)
10.20
Zero Speed/ASR1
Revision May 2009, 00DE, V0.50
Settings
0: Warn and keep operation
1: Warn and decelerate to stop
2: Warn and stop operation
0: Z signal is at the falling edge
of U-phase
1: Z signal is at the rising edge of
U-phase
0.0~500.0%
0.000~10.000 sec
0.0~500.0%
0.000~10.000 sec
0.0~500.0%
0.000~10.000 sec
0~4000RPM (0.00~400.0Hz)
0.000~0.350 sec
0~655.00%
0~4000RPM (0.00~400.0Hz)
Chapter 4 Parameters| BLD-E1 Series
Factory
VF VFPG FOCPM
Setting
2
0
100.0
0.200
100.0
0.200
100.0
0.200
7.00
0.008
80.00
5.00
4-25