Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Group 2 Digital Input/Output Parameters
2-wire/3-wire Operation Control
02-00
Control
VF
VFPG
mode
Settings
Three of the six methods include a "Line Start Lockout" feature. When line start lockout is
enabled, the drive will not run once applying the power. The Line Start Lockout feature
doesn't guarantee the motor will never start under this condition. It is possible the motor may
be set in motion by a malfunctioning switch.
This parameter is used to control operation from external terminals. There are three different
control modes.
2-wire operation control (1)
FWD/STOP
REV/STOP
2-wire operation control (2)
RUN/STOP
REV/FWD
3-wire operation control
4-48
FOCPM
0
FWD/STOP, REV/STOP
1
FWD/STOP, REV/STOP (Line Start Lockout)
2
RUN/STOP, REV/FWD
3
RUN/STOP, REV/FWD (Line Start Lockout)
4
3-wire
5
3-wire (Line Start Lockout)
02-00
0, 1
2, 3
4, 5
This parameter can be set during operation.
Control Circuits of the External Terminal
Factory setting: 0
Revision May 2009, 00DE, V0.50