Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
Maximum Torque Command
07-14
Control
FOCPM
mode
Settings
This parameter is for the max. torque command (motor rated torque is 100%).
Reserved
07-15
Reserved
07-16
Reserved
07-17
Reserved
07-18
Source of Torque Offset
07-19
Control
FOCPM
mode
Settings
This parameter is the source of torque offset.
When it is set to 3, the source of torque offset will decide to Pr.07-21, Pr.07-22 and Pr.07-23
by the multi-function input terminals setting (31, 32 or 33).
02-01~02-08 is set to 31 02-01~02-08 is set to 32 02-01~02-08 is set to 33
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Torque Offset Setting
07-20
Control
FOCPM
mode
Settings
This parameter is torque offset. The motor rated torque is 100%.
High Torque Offset
07-21
Control
FOCPM
mode
Settings
4-74
0 to 300%
0
Disable
1
Analog input (Pr.03-00)
2
Torque offset setting (Pr.07-20)
3
Control by external terminal (by Pr.07-21 to Pr.07-23)
OFF
OFF
ON
ON
OFF
OFF
ON
ON
0.0 to 100.0%
0.0 to 100.0%
Factory Setting: 100
Torque offset
OFF
ON
OFF
ON
07-23+07-22
OFF
ON
07-21+07-23
OFF
07-21+07-22
ON
07-21+07-22+07-23
Factory Setting: 0.0
Factory Setting: 30.0
Revision May 2009, 00DE, V0.50
Factory Setting: 0
None
07-23
07-22
07-21