Delta BLD-E1 Series User Manual page 78

Brushless motor dc drive
Table of Contents

Advertisement

Ramp to stop: the brushless DC decelerates the motor to Minimum Output Frequency
Pr.01-09 and stops according to the deceleration time set in Pr.01-07.
Coast to stop: the brushless DC drive stops output instantly upon command, and motor free
run until it comes to a complete stop.
If the machinery is turned off, the motor must also be stopped to avoid waste of power
for safety concern. It is suggested to set the brake ramp to stop with ramping duration
matches machinery characteristics.
As the machinery is turned off, if it is allowed for motor to spin freely or the inertia load is large,
it is suggested to set the motor to coast to stop.
Setting of Motor Running Direction
00-08
Control
VF
VFPG
mode
Settings
This parameter prevents the machine damage which caused by fwd/rev motor run error.
Control Method
00-09
Control
VF
VFPG
mode
Settings
Revision May 2009, 00DE, V0.50
FOCPM
0:reverse running allowed
1:reverse running not allowed
2:forward running not allowed
FOCPM
0
V/f control
1
V/f + Encoder (VFPG)
8
FOC PM control (FOCPM)
Chapter 4 Parameters| BLD-E1 Series
Factory setting: 0
Factory Setting: 0
and
4-37

Advertisement

Table of Contents
loading

Table of Contents