Chapter 2 Installation and Wiring| BLD-E1 Series
Figure 3 Wiring for NPN mode and PNP mode
NPN Mode
Factory setting is NPN
NP N
P NP
Factory
setting
NOTE
Don't apply mains voltage into above terminals.
PNP Mode
Factory setting is PNP
NP N
P NP
Factory
setting
NOTE
Don't apply mains voltage into above terminals.
CAUTION!
1.
The wiring of main circuit and control circuit should be separated to prevent erroneous actions.
2.
Please use shield wire for the control wiring and not to expose the peeled-off net in front of the
terminal.
3.
Please use the shield wire or tube for the power wiring and ground the two ends of the shield
wire or tube.
4.
Damaged insulation of wiring may cause personal injury or damage to circuits/equipment if it
comes in contact with high voltage.
5.
The brushless DC motor drive, motor and wiring may cause interference. To prevent the
equipment damage, please take care of the erroneous actions of the surrounding sensors and
the equipment.
2-4
Applicable Output Signal
Open collector output
Multi-function
input terminals
NOTE
It needs to connect O/P to multi-function
input terminals for normal operation.
Applicable Output Signal
Complementary output
Multi-function
input terminals
NOTE
It needs to connect O/P to multi-function
input terminals for normal operation.
VCC
O/P
0V
VCC
O/P
0V
Revision May 2009, 00DE, V0.50