Delta BLD-E1 Series User Manual page 130

Brushless motor dc drive
Table of Contents

Advertisement

Content
Status
monitor Read
only
Revision May 2009, 00DE, V0.50
Address
Bit 4-5
Bit 6-7
Bit 8-11
Bit 12
Bit 13~14
Bit 15
2001H
Frequency command
Bit 0
Bit 1
2002H
Bit 2
Bit 3-15
2100H
Error code: refer to Pr.06-16 to Pr.06-21
Bit 0-Bit 1
Bit 2
Bit 3-Bit 4
Bit 5
2119H
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13-15
2102H
Frequency command (F)
2103H
Output frequency (H)
2104H
Output current (AXXX.X)
2105H
DC-BUS Voltage (UXXX.X)
2106H
Output voltage (EXXX.X)
2107H
Current step number of Multi-Step Speed Operation
2116H
Multi-function display (Pr.00-04)
Chapter 4 Parameters| BLD-E1 Series
Function
00B: No function
01B: FWD
10B: REV
11B: Change direction
00B: 1st accel/decel
01B: 2nd accel/decel
10B: 3rd accel/decel
11B: 4th accel/decel
Represented 16 step speeds.
1: disable bit 06-11
00B: No function
01B: operated by digital keypad
02B: operated by Pr.00-15 setting
03B: change operation source
Reserved
1: EF (external fault) on
1: Reset
1: B.B. ON
Reserved
00: Stop
01: deceleration
10: Ready for operation
11: operation
1:JOG command
00: FWD command, FWD output
01: FWD command, REV output
10: REV command, FWD output
11: Reserved
Reserved
Reserved
Reserved
1: Master frequency Controlled by communication
interface
1: Master frequency controlled by analog/external
terminals signal
1: Operation command controlled by
communication interface
1: Parameters have been locked
1: enable to copy parameter from keypad
Reserved
4-89

Advertisement

Table of Contents
loading

Table of Contents