Monitoring Blower Assembly Status; Power Supply; Power Supply Led Descriptions - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2.
Type psShow to check power supply status.
The power supply status displays OK, Absent, or Faulty. If a power supply is absent or faulty,
contact HP to order replacement power supply.
Figure 23 Power supply
1. Power LED
Table 12
patterns.
Table 12 Power supply LED descriptions
LED pur-
pose
Power

Monitoring blower assembly status

To determine the status of a blower assembly:
1.
Check the LED indicators on the blower assembly (see
change during POST and other diagnostic tests; for information about how to interpret the LED
patterns, see
1
describes the power supply LED patterns and the recommended actions for those
Color
Status
No light (LED is
Power supply does not have incom-
off)
ing power and is not providing
power to the DC SAN Director.
Steady green
Power supply has incoming power
and is providing power to the DC
SAN Director.
Flashing green
Power supply is about to fail.
Table
13.
HP StorageWorks DC and DC04 SAN Backbone Director Switches
Recommended action
Ensure power supply is firmly
seated, DC SAN Director has incom-
ing power, both power cables are
connected, and AC power switches
are on.
No action required
Replace power supply.
Figure
24). The LED patterns may temporarily
26396a
69