Powering on the DC SAN Director

To power on the DC SAN Director:
CAUTION:
Use the supplied power cords. Ensure the facility power receptacle is the correct type, supplies the
required voltage, and is properly grounded.
1.
Connect the AC power cords to the power supply assemblies. One to four power cords are
required depending on electrical service.
2.
Connect the power cords to a power source with voltage of 200 to 240 VAC, 47 to 63 Hz
(normally two power cords) or to a power source with voltage of 110 to 120 VAC, 47 to 63 Hz
(two to four power cords).
TIP:
Use of the high-voltage line (200 to 240 VAC) is highly recommended due to better
power-conversion efficiency
3.
Turn the AC power switches on the power supplies to ON (I). The AC power switches light green
when switched on and power is supplied.
4.
The DC SAN Director performs a Power-on Self-Test (POST) each time it is powered on. POST
takes approximately 10 minutes and is complete when indicator light activity indicates the
operational state. For information about LED patterns, see
"Monitoring DC Director system
You can bypass POST by using the fastBoot command. You can also disable POST for
successive reboots on the DC SAN Director using the diagDisablePost command.
NOTE:
To prevent a potential IP address conflict, do not connect the DC SAN Director to the network
until the IP addresses are configured. See

Port numbering

The DC SAN Director uses the following port numbering method (see
"Port numbering
IMPORTANT:
Slots are numbered 1 through 12, from left to right when facing the port side of the DC SAN Director.
Control Processor blades (CP8) can be installed only in slots 6 and 7. Core switch blades (CR8) can
be installed only in slots 5 and 8.
FC8-16 port blade—ports are numbered from 0 through 15 from bottom to top.