HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual page 100

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3.
Record the DC SAN Director values on a workstation.
a.
Record the WWN value: Type wwn, then copy the command output into a file named
config-miscinfo.txt.
rsl8-st03-dcx-1:admin> wwn
10:00:00:60:69:00:00:0a
b.
Record the IP address information.
Type ipAddrShow -sw, then copy the command output into the config-miscinfo.txt
file.
rsl8-st03-dcx-1:admin> ipAddrShow —sw
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.6
Backplane IP address of CP1 : 10.0.0.7
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin
c.
Display and record the manufacturer serial numbers.
Type chassisShow, then copy the command output into the config-miscinfo.txt file.
"Factory Serial Num" and "Serial Num" are listed under "Chassis/WWN Unit 1." If the
current WWN cards are the original cards, the factory serial number listed is the same as
the chassis serial number.
rsl8-st03-dcx-1:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE
Slot: 1
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
<output truncated>
100
Replacing DC SAN Director field-replaceable units (FRUs)
2
-50
60-0001532-03
KP000000195
Day:
1
Month:
1
Day: 14
Month:
3
187 days
3 days
Year: 2007