Removing A Director Blade - HP A7533A - Brocade 4Gb SAN Switch Base Hardware Reference Manual

Hp storageworks dc and dc04 san backbone director switches hardware reference guide (5697-7814, february 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Phillips screwdriver
Small form-factor pluggable (SFP) or extended form-factor pluggable (XFP, FC10-6 Director blade
only) transceivers (as needed)
Optical cables (as needed)
WARNING!
A filler panel should be removed only when being replaced with a Director blade, or a filler panel.
Any slot that is not occupied by a Director blade should be occupied by a filler panel to ensure
correct cooling of the chassis and protection from dust.

Removing a Director blade

CAUTION:
Wear a grounded ESD strap when handling a Director blade. Use the grounding connections above
the power connectors on the chassis.
1.
Remove the chassis door. See
2.
A failed port or Director blade can be identified by inspecting the LEDs on the front panel of
each blade. Check the power LED, status LED, and port status LED to identify any possible
problems. See
3.
Establish a Telnet or console session.
Before replacing a blade, establish a Telnet or console connection to determine a failure and
verify operation after replacement. Use the switchShow command to view the status of blades.
4.
Check for adequate cable slack. Ensure there is plenty of cable slack to remove a blade without
cable obstruction.
5.
Ensure that the part number on the unit being replaced matches the replacement part number.
The chassisShow command displays information about the blades, including part numbers
(xx-000xxxx-xx), serial numbers, and additional status.
6.
Ensure that traffic is not flowing through the blade (port status LED should be off) prior to
disconnecting cables.
NOTE:
Before removing any cables from a blade, note the cable order (identify each cable by its
physical port). If multiple blades are being replaced, replace one blade at a time.
7.
Ensure that traffic is not flowing through the blade.
8.
Disconnect all cables and SFP or XFP transceivers from the blade.
76
Replacing DC SAN Director field-replaceable units (FRUs)
"Removing the chassis
"Monitoring DC Director system
door" on page 73.
components" on page 57 for LED locations.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents